IC-GM800
Specifications
General | |
Frequency Range Tx Rx DSC | 1.6–27.5000MHz (ITU marine channels) 0.5–29.9999MHz (continuously) 2.1875, 4.2075, 6.3120, 8.4145, 12.5770, 16.8045MHz |
Type of emission Tx/Rx DSC | J3E (USB/LSB*), J2B (AFSK), F1B (FSK), A1A* (CW), H3E* (AM) F1B * Receive only |
Number of channels | 1237 channels (maximum) (160 user-programmable; 249 ITU SSB duplex; 72 ITU SSB simplex; 21 C1; 31 C2; 704 ITU FSK duplex) |
Power supply requirement | 21.6–31.2V DC (24V DC) (floating ground) |
Current drain (with PS-310 #01) Tx Maximum power Rx Maximum audio | Less than 20A (at 1.1kHz and 1.7kHz two tones) Less than 3A |
Operating temperature range | –15°C to +55°C |
Antenna Impedance | 50Ω (SO-239×2) |
Frequency stability Tx/Rx DSC | ±10Hz (0.5–29.9999MHz) ±10Hz |
NMEA Interface | GGA, GNS, GLL, RMC |
Transmitter | |
Rated output power (at AT-141 output power) | 85W PEP (1.6–3.999MHz) 125W PEP (4.0–27.500MHz) |
Spurious emissions | 43dB below peak output power (Maximum power) |
Carrier suppression | 40dB below peak output power (Maximum power) |
Unwanted sideband suppression | 55dB below peak output power (Max. power) (With 1000Hz AF input) |
Receiver | |
Sensitivity J3E, A1A (20dB SINAD) H3E (20dB SINAD) J2B, F1B (1% error rate) DSC (J2B) (1% error rate) | |
Squelch sensitivity (at signal strength meter) J3E H3E | Less than +20dBμV/Less than +90dBμV (at 12.230MHz) (Threshold/Tight) Less than +30dBμV/Less than +110dBμV (at 1.000MHz) (Threshold/Tight) |
Spurious response rejection J3E J2B | More than 60dB (0.5–29.999MHz) More than 90dBμV emf. |
Audio output power Internal SP External SP | 2W with 8Ω load (at 10% distortion) 4W with 4Ω load (at 10% distortion) |
Clarity variable range | ±150Hz |
0.5–1.599MHz 1.6–3.999MHz 4.0–29.999MHz 0.5–1.599MHz 1.6–3.999MHz 4.0–29.999MHz 1.6–2.099MHz 2.1–27.500MHz | 30dBμV emf. 16dBμV emf. 11dBμV emf. 44dBμV emf. 30dBμV emf. -- .3dBμV emf. 0dBμV emf. |
0dBμV emf. (2.1875, 4.2075, 6.3120, 8.4145, 12.5770, 16.8045MHz) |
All stated specifications are subject to change without notice or obligation.
Applicable IP Rating
Ingress Protection Standard | |
Water | IPX7 (1m depth of water for 30 minutes -controller only) |
Supplied Accessories
§ Handset, HS-98
§ Mounting brackets
§ DC power cable